Journal of the Chinese Medical Association
Volume 71, Issue 8 , Pages 399-405, August 2008

Sizing of Atrial Septal Defects by Intracardiac Echocardiography for Device Closures

  • Jen-Chung Chien

      Affiliations

    • Department of Pediatrics, Lo-Tung Pohai Hospital, Ilan, Taiwan, R.O.C.
    • Department of Pediatrics, Taipei Veterans General Hospital, Taiwan, R.O.C.
  • ,
  • Betau Hwang

      Affiliations

    • Department of Pediatrics, Taipei Veterans General Hospital, Taiwan, R.O.C.
    • Department of Pediatrics, Zhongxiao Branch, Taipei City Hospital, Taiwan, R.O.C.
    • Department of Pediatrics, National Yang-Ming University School of Medicine, Taipei, Taiwan, R.O.C.
    • Corresponding Author InformationCorrespondence to: Dr Betau Hwang, Department of Pediatrics, Zhongxiao Branch, Taipei City Hospital, 87, Tongde Road, Nangang District, Taipei 115, Taiwan, R.O.C.
  • ,
  • Yun-Ching Fu

      Affiliations

    • Department of Pediatrics, National Yang-Ming University School of Medicine, Taipei, Taiwan, R.O.C.
    • Department of Pediatrics, Taichung Veterans General Hospital, Taichung, Taiwan, R.O.C.
  • ,
  • Pi-Chang Lee

      Affiliations

    • Department of Pediatrics, Taipei Veterans General Hospital, Taiwan, R.O.C.
    • Department of Pediatrics, National Yang-Ming University School of Medicine, Taipei, Taiwan, R.O.C.
  • ,
  • Kai-Sheng Hsieh

      Affiliations

    • Department of Pediatrics, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan, R.O.C.
  • ,
  • Sheng-Ling Jan

      Affiliations

    • Department of Pediatrics, National Yang-Ming University School of Medicine, Taipei, Taiwan, R.O.C.
    • Department of Pediatrics, Taichung Veterans General Hospital, Taichung, Taiwan, R.O.C.

Received 29 February 2008; accepted 18 June 2008.

Article Outline

Background

Transcatheter closure of a secundum atrial septal defect (ASD) has become an effective method for surgical treatment. In this study, we evaluated the feasibility and accuracy of intracardiac echocardiography (ICE) for sizing ASDs compared with conventional methods.

Methods

Between January 2004 and December 2006, 270 patients underwent transcatheter closure of secundum ASD by using septal occluders. For 142 patients, the procedure was guided by transesophageal echocardiography (TEE), and for 128 patients by ICE. We compared the maximal diameters of the ASDs obtained during angiocardiography, transthoracic echocardiography (TTE), ICE, and TEE with balloon-stretched sizes ascertained by using a sizing plate.

Results

ASD diameters measured with the sizing plate were significantly correlated with those measured with ICE (r = 0.963), TEE (r = 0.912), angiography (r = 0.88), and TTE (r = 0.85). The predicted stretched diameter of the ASDs, i.e. (nonstretched diameter measured with ICE ×1.07) +3.23 mm, agreed well with that measured by using a sizing plate (Ri = 0.974).

Conclusion

ASD diameters measured with ICE correlated with sizing-plate measurements better than those determined with TEE, angiography or TTE.

Key Words:  atrial septal defect , intracardiac echocardiography , transcatheter closure

No full text is available. To read the body of this article, please view the PDF online.

 

Back to Article Outline

References 

  1. Masura J , Gavora P , Formanek A , Hijazi ZM . Transcatheter closure of secundum atrial septal defects using the new selfcentering Amplatzer septal occluder: initial human experience . Cathet Cardiovasc Diagn . 1997;42:388–393
  2. Earing MG , Cabalka AK , Seward JB , Bruce CJ , Reeder GS , Hagler DJ . Intracardiac echocardiographic guidance during transcatheter device closure of atrial septal defect and patent foramen ovale . Mayo Clin Proc . 2004;79:24–34
  3. Wang JK , Tsai SK , Wu MH , Lin MT , Lue HC . Short and intermediate-term results of transcatheter closure of atrial septal defect with the Amplatzer septal occluder . Am Heart J . 2004;148:511–517
  4. Ho CL, Liang KW, Fu YC, Jan SL, Lin MC, Chi CS, et al. Transcatheter therapy of Lutembacher syndrome . J Chin Med Assoc . 2007;70:253–256
  5. Hellebrand WE , Fahey JT , McGowan FX , Weltin GG , Kleinman CS . Transesophageal echocardiography guidance of transcatheter closure of atrial septal defect . Am J Cardiol . 1990;66:207–213
  6. Godart F , Rey C , Francart C , Jarrar M , Vaksmann G . Twodimensional echocardiographic and color Doppler measurements of atrial septal defect, and comparison with the balloon stretched diameter . Am J Cardiol . 1993;72:1095–1097
  7. Hijazi ZM , Cao Q , Patel HT , Rhodes J , Hanlon KM . Transesophageal echocardiographic results of catheter closure of atrial septal defect in children and adults using the Amplatzer device . Am J Cardiol . 2000;85:1387–1390
  8. Bartel T, Konorza T, Neudorf U, Ebralize T, Eggebrecht H, Gutersohn A, et al. Intracardiac echocardiography: an ideal guiding tool for device closure of interatrial communications . Eur J Echocardiography . 2005;6:92–96
  9. Alboliras ET , Hijazi ZM . Comparison of costs of intracardiac echocardiography and transesophageal echocardiography in monitoring percutaneous device closure of atrial septal defect in children and adults . Am J Cardiol . 2004;94:690–692
  10. Boccalandro F, Muench A, Salloum J, Awadalla H, Carter C, Barasch E, et al. Interatrial defect sizing by intracardiac and transesophageal echocardiography compared with fluoroscopic measurements in patients undergoing percutaneous transcatheter closure . Catheter Cardiovasc Interv . 2004;62:415–420
  11. Koenig P , Cao QL . Echocardiographic guidance of transcatheter closure of atrial septal defects: is intracardiac echocardiography better than transesophageal echocardiography? . Pediatr Cardiol . 2005;26:135–139
  12. Hijazi ZM , Wang Z , Cao QL , Koenig P , Waight D , Lang R . Transcatheter closure of atrial septal defects and patent foramen ovale under intracardiac echocardiographic guidance: feasibility and comparison with transesophageal echocardiography . Cathet Cardiovasc Intervent . 2001;52:194–199
  13. Mullen MJ , Dias BF , Walker F , Siu SC , Benson LN , McLaughlin PR . Intracardiac echocardiography guided device closure of atrial septal defects . J Am Coll Cardiol . 2003;41:285–292
  14. Chan KC , Godman MJ , Walsh K , Wilson N , Redington A , Gibbs JL . Transcatheter closure of atrial septal defect and interatrial communications with a new self expanding nitinol double disc device (Amplatzer septal occluder): multicentre UK experience . Heart . 1999;82:300–306
  15. O'Leary PW . Intracardiac echocardiography in congenital heart disease: are we ready to begin the fantastic voyage? . Pediatr Cardiol . 2002;23:286–291
  16. El-Said HG, Bezold LI, Grifka RG, Pignatelli RH, McMahon CJ, Schutte DA, et al  Sizing of atrial septal defects to predict successful closure with transcatheter CardioSEAL device . Tex Heart Inst J . 2001;28:177–182
  17. Jan SL , Hwang B , Lee PC , Fu YC , Chiu PS , Chi CS . Intracardiac ultrasound assessment of atrial septal defect: comparison with transthoracic echocardiographic, angiocardiographic, and balloonsizing measurements . Cardiovasc Intervent Radiol . 2001;24:84–89
  18. Carlson KM, Justino H, O'Brien RE, Dimas VV, Leonard GT, Pignatelli RH, et al  Transcatheter atrial septal defect closure: modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer device occluder . Cathet Cardivasc Intervent . 2005;65:390–396
  19. Zhu W , Cao QL , Rhodes J , Hijazi ZM . Measurement of atrial septal defect size: a comparative study between three-dimensional transesophageal echocardiography and the standard balloon sizing methods . Pediatr Cardiol . 2000;21:465–469
  20. Bruce CJ , Friedman PA . Intracardiac echocardiography . Eur J Echocardiography . 2001;2:234–244
  21. Koenig PR , Abdulla R , Cao QL , Hijazi ZM . Use of intracardiac echocardiography to guide catheter closure of atrial communications . Echocardiography . 2003;20:781–787
  22. Boccalandro F , Baptista E , Muench A , Carter C , Smalling RW . Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect . Am J Cardiol . 2004;93:437–440
  23. Zanchetta M, Rigatelli G, Pedon L, Zennaro M, Carrozza A, Onorato E, et al. Transcatheter atrial septal defect closure assisted by intracardiac echocardiography: 3-year follow-up . J Interven Cardiol . 2004;17:95–98
  24. Koenig P , Cao QL , Heitschmidt M , Waight DJ , Hijazi ZM . Role of intracardiac echocardiographic guidance in transcatheter closure of atrial septal defects and patent foramen ovale using the Amplatzer device . J Interven Cardiol . 2003;16:51–62
  25. Hijazi ZM , Cao QL , Heitschmidt M , Lang MR . Residual inferior atrial septal defect after surgical repair: closure under intracardiac echocardiographic guidance . J Invas Cardiol . 2001;13:810–813
  26. Light ED , Idriss SF , Wolf PD , Smith SW . Real-time threedimensional intracardiac echocardiography . Ultrasound Med Biol . 2001;27:1177–1183

PII: S1726-4901(08)70090-X

doi:10.1016/S1726-4901(08)70090-X

Journal of the Chinese Medical Association
Volume 71, Issue 8 , Pages 399-405, August 2008